livingstonT1E1PhysType

Module: LIVINGSTON-SNMP

OID (symbolic): LIVINGSTON-SNMP::livingstonT1E1PhysType

OID (numeric): 1.3.6.1.4.1.307.3.2.2.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The type of interface (T1 or E1).

What is livingstonT1E1PhysType?

This reports whether the interface is configured as t1(1) or e1(2). Use this to confirm the correct telco standard is configured for the line actually connected, since T1 and E1 use different framing and channel counts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.307.3.2.2.1.1.2
snmpwalk -v2c -c public <target> LIVINGSTON-SNMP::livingstonT1E1PhysType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.307.3.2.2.1.1.2.1
snmpget -v2c -c public <target> LIVINGSTON-SNMP::livingstonT1E1PhysType.1

Start monitoring Livingston PortMaster dial-up access server / IRX router with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIVINGSTON-SNMP::livingstonT1E1PhysType OID value, configure state conditions and alerts, and monitor any Livingston PortMaster dial-up access server / IRX router from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.307livingstonLIVINGSTON-SNMP
1.3.6.1.4.1.307.3livingstonMibLIVINGSTON-SNMP
1.3.6.1.4.1.307.3.2livingstonInterfacesLIVINGSTON-SNMP
1.3.6.1.4.1.307.3.2.2livingstonT1E1LIVINGSTON-SNMP
1.3.6.1.4.1.307.3.2.2.1livingstonT1E1TableLIVINGSTON-SNMP
1.3.6.1.4.1.307.3.2.2.1.1livingstonT1E1EntryLIVINGSTON-SNMP
1.3.6.1.4.1.307.3.2.2.1.1.2livingstonT1E1PhysTypeLIVINGSTON-SNMP