LIEBERT-GP-PDU-MIB :: lgpPduPsEntryWiringType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-PDU-MIB › lgpPduPsEntryWiringType

lgpPduPsEntryWiringType

Module: LIEBERT-GP-PDU-MIB

OID (symbolic): LIEBERT-GP-PDU-MIB::lgpPduPsEntryWiringType

OID (numeric): 1.3.6.1.4.1.476.1.42.3.8.30.20.1.25

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The PDU's power supply physical wiring type. not-specified The type has not been specified/configured. The end_user must configure this object to specify the physical wiring type. single-phase-3-wire-L1-N-PE Single Phase input with 3 wires (Line 1, Neutral and Protective Earth). two-phase-3-wire-L1-L2-PE Two Phase input with 3 wires (Line 1, Line 2, and Protective Earth). three-phase-4-wire-L1-L2-L3-PE Three Phase input with 4 wires (Line 1, Line 2, Line 3, and Protective Earth). three-phase-5-wire-L1-L2-L3-N-PE Three Phase input with 5 wires (Line 1, Line 2, Line 3, Neutral and Protective Earth). two-phase-4-wire-L1-L2-N-PE Two Phase input with 4 wires (Line 1, Line 2, Neutral, and Protective Earth).

What is lgpPduPsEntryWiringType?

An enumerated, read-write field describing the physical wiring topology of the power source's input, e.g. three-phase-5-wire-L1-L2-L3-N-PE(4) for a 3-phase wye feed with neutral and ground. A value of not-specified(0) means an admin still needs to configure it so downstream voltage/current interpretation (line-to-line vs. line-to-neutral) is correct.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.8.30.20.1.25
snmpwalk -v2c -c public <target> LIEBERT-GP-PDU-MIB::lgpPduPsEntryWiringType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.8.30.20.1.25.1
snmpget -v2c -c public <target> LIEBERT-GP-PDU-MIB::lgpPduPsEntryWiringType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.8.30.20.1.25.1 i <value>

Start monitoring Liebert/Emerson power distribution units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-PDU-MIB::lgpPduPsEntryWiringType OID value, configure state conditions and alerts, and monitor any Liebert/Emerson power distribution units from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.8lgpPduLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.8.30lgpPduPowerSourceLIEBERT-GP-PDU-MIB
1.3.6.1.4.1.476.1.42.3.8.30.20lgpPduPsTableLIEBERT-GP-PDU-MIB
1.3.6.1.4.1.476.1.42.3.8.30.20.1lgpPduPsEntryLIEBERT-GP-PDU-MIB
1.3.6.1.4.1.476.1.42.3.8.30.20.1.25lgpPduPsEntryWiringTypeLIEBERT-GP-PDU-MIB