All MIBs › LIEBERT-GP-PDU-MIB › lgpPduAuxSensorTempThrshldOvrWarnDegC
lgpPduAuxSensorTempThrshldOvrWarnDegC
Module: LIEBERT-GP-PDU-MIB
OID (symbolic): LIEBERT-GP-PDU-MIB::lgpPduAuxSensorTempThrshldOvrWarnDegC
OID (numeric): 1.3.6.1.4.1.476.1.42.3.8.60.10.1.95
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: Over temperature warning threshold. A warning is activated if the temperature is equal to or above this value.
What is lgpPduAuxSensorTempThrshldOvrWarnDegC?
A read-write over-temperature warning threshold in tenths of a degree Celsius, giving early notice before the over-temperature alarm threshold is reached.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.8.60.10.1.95 snmpwalk -v2c -c public <target> LIEBERT-GP-PDU-MIB::lgpPduAuxSensorTempThrshldOvrWarnDegC
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.8.60.10.1.95.1 snmpget -v2c -c public <target> LIEBERT-GP-PDU-MIB::lgpPduAuxSensorTempThrshldOvrWarnDegC.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.8.60.10.1.95.1 i <value>
Start monitoring Liebert/Emerson power distribution units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-PDU-MIB::lgpPduAuxSensorTempThrshldOvrWarnDegC OID value, configure state conditions and alerts, and monitor any Liebert/Emerson power distribution units from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.476 | emerson | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1 | liebertCorp | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42 | liebertGlobalProducts | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3 | lgpFoundation | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3.8 | lgpPdu | LIEBERT-GP-REGISTRATION-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.476.1.42.3.8.60 | lgpPduAuxiliarySensors | LIEBERT-GP-PDU-MIB |
| 1.3.6.1.4.1.476.1.42.3.8.60.10 | lgpPduAuxSensorTable | LIEBERT-GP-PDU-MIB |
| 1.3.6.1.4.1.476.1.42.3.8.60.10.1 | lgpPduAuxSensorEntry | LIEBERT-GP-PDU-MIB |
| 1.3.6.1.4.1.476.1.42.3.8.60.10.1.95 | lgpPduAuxSensorTempThrshldOvrWarnDegC | LIEBERT-GP-PDU-MIB |