KERNEL-READER-SUNMANAGEMENTCENTER-MIB :: krDiskSrvcAvgTransTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › KERNEL-READER-SUNMANAGEMENTCENTER-MIB › krDiskSrvcAvgTransTime

krDiskSrvcAvgTransTime

Module: KERNEL-READER-SUNMANAGEMENTCENTER-MIB

OID (symbolic): KERNEL-READER-SUNMANAGEMENTCENTER-MIB::krDiskSrvcAvgTransTime

OID (numeric): 1.3.6.1.4.1.42.2.12.2.2.12.3.2.1.1.6

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: The average service (run + wait) time in msec for one disk transaction, either read or write.

What is krDiskSrvcAvgTransTime?

Average total service time in milliseconds per transaction (run time plus wait time combined), giving the end-to-end latency an application would experience for a disk I/O.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.12.2.2.12.3.2.1.1.6
snmpwalk -v2c -c public <target> KERNEL-READER-SUNMANAGEMENTCENTER-MIB::krDiskSrvcAvgTransTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.12.2.2.12.3.2.1.1.6.1
snmpget -v2c -c public <target> KERNEL-READER-SUNMANAGEMENTCENTER-MIB::krDiskSrvcAvgTransTime.1

Start monitoring Sun/Solaris server managed via Sun Management Center with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the KERNEL-READER-SUNMANAGEMENTCENTER-MIB::krDiskSrvcAvgTransTime OID value, configure state conditions and alerts, and monitor any Sun/Solaris server managed via Sun Management Center from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.42sunAGENT-STATS-MIB2
1.3.6.1.4.1.42.2prodAGENT-STATS-MIB2
1.3.6.1.4.1.42.2.12sunsymonAGENT-STATS-MIB2
1.3.6.1.4.1.42.2.12.2agentAGENT-STATS-MIB2
1.3.6.1.4.1.42.2.12.2.2modulesAGENT-STATS-MIB2
1.3.6.1.4.1.42.2.12.2.2.12kernelReaderKERNEL-READER-SIMPLE-MIB2
Numeric OIDNameModule
1.3.6.1.4.1.42.2.12.2.2.12.3krDiskKERNEL-READER-SUNMANAGEMENTCENTER-MIB
1.3.6.1.4.1.42.2.12.2.2.12.3.2krDiskSrvcTimeGroupKERNEL-READER-SUNMANAGEMENTCENTER-MIB
1.3.6.1.4.1.42.2.12.2.2.12.3.2.1krDiskSrvTableKERNEL-READER-SUNMANAGEMENTCENTER-MIB
1.3.6.1.4.1.42.2.12.2.2.12.3.2.1.1krDiskSrvEntryKERNEL-READER-SUNMANAGEMENTCENTER-MIB
1.3.6.1.4.1.42.2.12.2.2.12.3.2.1.1.6krDiskSrvcAvgTransTimeKERNEL-READER-SUNMANAGEMENTCENTER-MIB