Juniper-AUTOCONFIGURE-MIB :: juniAutoConfNextLockoutTime

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › Juniper-AUTOCONFIGURE-MIB › juniAutoConfNextLockoutTime

juniAutoConfNextLockoutTime

Module: Juniper-AUTOCONFIGURE-MIB

OID (symbolic): Juniper-AUTOCONFIGURE-MIB::juniAutoConfNextLockoutTime

OID (numeric): 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.9

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The time duration, in seconds, that will be used to lockout the specified encapsulation type from recognition for the specified interface for the next event that results in a lockout condition. The reported value is within the range specified by juniAutoConfLockoutMin and juniAutoConfLockoutMax. When juniAutoConfEnable is set to enable, a value of 0 indicates that lockout is prevented from occurring for the encapsulation type for the specified interface (i.e., juniAutoConfLockoutMin and juniAutoConfLockoutMax are both set to 0).

What is juniAutoConfNextLockoutTime?

This read-only value, in seconds, reports the lockout duration that will be applied the next time a creation error triggers a lockout for this encapsulation type and interface, staying within the juniAutoConfLockoutMin/Max range; when autoconfiguration is enabled a value of 0 means lockout has been disabled for this pair. Admins use it to anticipate how the exponential backoff will escalate if the failure recurs. For example, seeing juniAutoConfNextLockoutTime climb from 4 to 8 seconds after a lockout event shows the exponential backoff doubling in response to repeated failures.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.9
snmpwalk -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfNextLockoutTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.9.1
snmpget -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfNextLockoutTime.1

Start monitoring Juniper Networks E-series broadband access routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Juniper-AUTOCONFIGURE-MIB::juniAutoConfNextLockoutTime OID value, configure state conditions and alerts, and monitor any Juniper Networks E-series broadband access routers from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4874juniperUniJuniper-UNI-SMI
1.3.6.1.4.1.4874.2juniperUniMibsJuniper-UNI-SMI
1.3.6.1.4.1.4874.2.2juniMibsJuniper-MIBs
Numeric OIDNameModule
1.3.6.1.4.1.4874.2.2.48juniAutoConfMIBJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1juniAutoConfObjectsJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1juniAutoConfJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1juniAutoConfTableJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1.1juniAutoConfEntryJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.9juniAutoConfNextLockoutTimeJuniper-AUTOCONFIGURE-MIB