Juniper-AUTOCONFIGURE-MIB :: juniAutoConfLockoutSupported

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › Juniper-AUTOCONFIGURE-MIB › juniAutoConfLockoutSupported

juniAutoConfLockoutSupported

Module: Juniper-AUTOCONFIGURE-MIB

OID (symbolic): Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutSupported

OID (numeric): 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.4

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Indicates whether lockout is supported for the specified encapsulation type for the specified interface. If lockout is supported, then juniAutoConfLockoutMin, juniAutoConfLockoutMax, juniAutoConfLockoutTime, juniAutoConfLockoutElapsedTime, and juniAutoConfNextLockoutTime are valid and supported in this entry.

What is juniAutoConfLockoutSupported?

This read-only boolean indicates whether the lockout feature is supported for a given encapsulation type on a given interface, and if true means the related lockout-timing objects (juniAutoConfLockoutMin, Max, Time, ElapsedTime, NextLockoutTime) are valid for this entry. Admins check it before relying on the lockout timing objects, since unsupported combinations leave those objects meaningless. For example, a value of false on a given interface/encapsulation entry tells the admin not to expect the lockout timers to reflect real behavior there.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.4
snmpwalk -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutSupported

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.4.1
snmpget -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutSupported.1

Start monitoring Juniper Networks E-series broadband access routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutSupported OID value, configure state conditions and alerts, and monitor any Juniper Networks E-series broadband access routers from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4874juniperUniJuniper-UNI-SMI
1.3.6.1.4.1.4874.2juniperUniMibsJuniper-UNI-SMI
1.3.6.1.4.1.4874.2.2juniMibsJuniper-MIBs
Numeric OIDNameModule
1.3.6.1.4.1.4874.2.2.48juniAutoConfMIBJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1juniAutoConfObjectsJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1juniAutoConfJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1juniAutoConfTableJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1.1juniAutoConfEntryJuniper-AUTOCONFIGURE-MIB
1.3.6.1.4.1.4874.2.2.48.1.1.1.1.4juniAutoConfLockoutSupportedJuniper-AUTOCONFIGURE-MIB