All MIBs › Juniper-AUTOCONFIGURE-MIB › juniAutoConfLockoutMax
juniAutoConfLockoutMax
Module: Juniper-AUTOCONFIGURE-MIB
OID (symbolic): Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutMax
OID (numeric): 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The upper bound, in seconds, of the time range used to specify the duration of the lockout of the encapsulation type from recognition for the specified interface. This value must equal or exceed the value for juniAutoConfLockoutMin. This only takes effect if juniAutoConfEnable is set to enable for the encapsulation type for this interface. The ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type is enabled by default. The initial lockout duration is juniAutoConfLockoutMin and increases exponentially for each failure that occurs for the specified encapsulation type for the specified interface within the greater of 15 minutes and this object's value. The lockout duration for the specified encapsulation type will not exceed this object's value. If the time between creation errors for the specified encapsulation type for the specified interface is greater than the greater of 15 minutes and this object's value, then the lockout duration reverts to juniAutoConfigLockoutMin. To disable the ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type for the specified interface, the value of this object and juniAutoConfLockoutMin must be set to 0. It is not recommended that this lockout feature be disabled except for debugging purposes.
What is juniAutoConfLockoutMax?
This read-write value, in seconds (0-86400, default 300), sets the upper bound on how long an encapsulation type can be locked out of autoconfiguration recognition after repeated creation errors, and must be at least as large as juniAutoConfLockoutMin. Admins raise it to allow longer backoff periods for a persistently failing encapsulation type, capping the exponential growth from juniAutoConfLockoutMin. For example, leaving juniAutoConfLockoutMax at its default of 300 means the lockout duration will never grow beyond 5 minutes no matter how many repeated failures occur.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6 snmpwalk -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutMax
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6.1 snmpget -v2c -c public <target> Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutMax.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6.1 i <value>
Start monitoring Juniper Networks E-series broadband access routers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Juniper-AUTOCONFIGURE-MIB::juniAutoConfLockoutMax OID value, configure state conditions and alerts, and monitor any Juniper Networks E-series broadband access routers from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4874 | juniperUni | Juniper-UNI-SMI |
| 1.3.6.1.4.1.4874.2 | juniperUniMibs | Juniper-UNI-SMI |
| 1.3.6.1.4.1.4874.2.2 | juniMibs | Juniper-MIBs |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4874.2.2.48 | juniAutoConfMIB | Juniper-AUTOCONFIGURE-MIB |
| 1.3.6.1.4.1.4874.2.2.48.1 | juniAutoConfObjects | Juniper-AUTOCONFIGURE-MIB |
| 1.3.6.1.4.1.4874.2.2.48.1.1 | juniAutoConf | Juniper-AUTOCONFIGURE-MIB |
| 1.3.6.1.4.1.4874.2.2.48.1.1.1 | juniAutoConfTable | Juniper-AUTOCONFIGURE-MIB |
| 1.3.6.1.4.1.4874.2.2.48.1.1.1.1 | juniAutoConfEntry | Juniper-AUTOCONFIGURE-MIB |
| 1.3.6.1.4.1.4874.2.2.48.1.1.1.1.6 | juniAutoConfLockoutMax | Juniper-AUTOCONFIGURE-MIB |