JUNIPER-POWER-SUPPLY-UNIT-MIB :: jnxPsuOutletPowerFactorValue

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › JUNIPER-POWER-SUPPLY-UNIT-MIB › jnxPsuOutletPowerFactorValue

jnxPsuOutletPowerFactorValue

Module: JUNIPER-POWER-SUPPLY-UNIT-MIB

OID (symbolic): JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuOutletPowerFactorValue

OID (numeric): 1.3.6.1.4.1.2636.3.58.1.2.4.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Power factor percentage of each PSU (2k/3k).

Algorithm for calculation of Power Factor is below. For PowerOut values that fall in between 618.93W and 915.24W, say 700W, the appropriate PF ranges from 0.910191 & 0.917994. Following linear equation could help deduce a fairly accurate input power value.

Linear equation y = mx + b (where m is the slope and b is the Y intercept)

Slope m = (y2 - y1) / (x2 - x1) Y intercept b = y - mx

Plugging it all together for our example:

m = (915.24 - 618.93) / (0.917994 - 0.910191) = 37973.86 b = 915.24 - (37973.86 * 0.917994) = -33944.5

for 700W (y), our efficiency (x) would then be:

x = (700 - (-33944.5)) / 37973.86 = 0.912326 = 91%

PowerIn = 700W /0.912326 = 767.26W

What is jnxPsuOutletPowerFactorValue?

Reports an efficiency percentage for this outlet's PSU (power output divided by power input, not the traditional watts-over-VA power factor); the MIB documents a linear formula an admin can use to derive input power from a given output power and this efficiency value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2636.3.58.1.2.4.1.10
snmpwalk -v2c -c public <target> JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuOutletPowerFactorValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2636.3.58.1.2.4.1.10.1
snmpget -v2c -c public <target> JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuOutletPowerFactorValue.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> jnxPsuOutletPowerFactorValue.1

Start monitoring Juniper Networks chassis-based router/switch (power supply unit health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the JUNIPER-POWER-SUPPLY-UNIT-MIB::jnxPsuOutletPowerFactorValue OID value, configure state conditions and alerts, and monitor any Juniper Networks chassis-based router/switch (power supply unit health) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2636juniperMIBJUNIPER-SMI
1.3.6.1.4.1.2636.3jnxMibsJUNIPER-SMI
1.3.6.1.4.1.2636.3.58jnxPsuMIBRootJUNIPER-SMI
Numeric OIDNameModule
1.3.6.1.4.1.2636.3.58.1jnxPsuMIBJUNIPER-POWER-SUPPLY-UNIT-MIB
1.3.6.1.4.1.2636.3.58.1.2jnxPsuObjectsJUNIPER-POWER-SUPPLY-UNIT-MIB
1.3.6.1.4.1.2636.3.58.1.2.4jnxPsuOutletTableJUNIPER-POWER-SUPPLY-UNIT-MIB
1.3.6.1.4.1.2636.3.58.1.2.4.1jnxPsuOutletEntryJUNIPER-POWER-SUPPLY-UNIT-MIB
1.3.6.1.4.1.2636.3.58.1.2.4.1.10jnxPsuOutletPowerFactorValueJUNIPER-POWER-SUPPLY-UNIT-MIB