IRM3-MIB :: bdCollsBdDisable

MIB Reference — IPNetwork Monitor · Updated September 29, 2026

All MIBs › IRM3-MIB › bdCollsBdDisable

bdCollsBdDisable

Module: IRM3-MIB

OID (symbolic): IRM3-MIB::bdCollsBdDisable

OID (numeric): 1.3.6.1.4.1.52.1.2.1.9.2.2.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Permit a board to be disabled on a collision threshold alarm.

What is bdCollsBdDisable?

Permits this board to be automatically disabled when its collision threshold alarm fires, turning the collision alarm into an automatic protective action rather than just a notification.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.1.2.1.9.2.2.3
snmpwalk -v2c -c public <target> IRM3-MIB::bdCollsBdDisable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.1.2.1.9.2.2.3.1
snmpget -v2c -c public <target> IRM3-MIB::bdCollsBdDisable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.1.2.1.9.2.2.3.1 i <value>

Start monitoring Cabletron Systems modular chassis device (hub/switch/concentrator) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IRM3-MIB::bdCollsBdDisable OID value, configure state conditions and alerts, and monitor any Cabletron Systems modular chassis device (hub/switch/concentrator) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.1commsDeviceCabletron-MIB
1.3.6.1.4.1.52.1.2repeaterCabletron-MIB
1.3.6.1.4.1.52.1.2.1repeaterRev1Cabletron-MIB
1.3.6.1.4.1.52.1.2.1.9alarmCabletron-MIB
1.3.6.1.4.1.52.1.2.1.9.2bdAlrmCabletron-MIB
1.3.6.1.4.1.52.1.2.1.9.2.2bdCollsCabletron-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.1.2.1.9.2.2.3bdCollsBdDisableIRM3-MIB