IMCO-LS110-MIB :: sdsTempSensValue

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › IMCO-LS110-MIB › sdsTempSensValue

sdsTempSensValue

Module: IMCO-LS110-MIB

OID (symbolic): IMCO-LS110-MIB::sdsTempSensValue

OID (numeric): 1.3.6.1.4.1.33283.1.30.5.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Temperature Sensor (C) multiplied by 100.

What is sdsTempSensValue?

Current reading from the analog temperature sensor, in degrees Celsius multiplied by 100 (so divide the returned value by 100 to get actual °C). Poll this for site environmental monitoring; the paired sdsTempSensValue-trap can alert you when it changes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33283.1.30.5.1.3
snmpwalk -v2c -c public <target> IMCO-LS110-MIB::sdsTempSensValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33283.1.30.5.1.3.1
snmpget -v2c -c public <target> IMCO-LS110-MIB::sdsTempSensValue.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sdsTempSensValue.1

Start monitoring ViaNet.sk environmental/power monitoring units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IMCO-LS110-MIB::sdsTempSensValue OID value, configure state conditions and alerts, and monitor any ViaNet.sk environmental/power monitoring units from a single console.

How to Use in IPNetwork Monitor

Select a ViaNet.sk environmental/power monitoring unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sdsTempSensValue into the Find box to locate it in the OID tree, then select it and click OK. It reports the temperature Sensor (C) multiplied by 100. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33283mib_AN_Dcz_SDSIMCO-LS110-MIB
1.3.6.1.4.1.33283.1sdsxpublicIMCO-LS110-MIB
1.3.6.1.4.1.33283.1.30sdsBIGandSTSWIMCO-LS110-MIB
1.3.6.1.4.1.33283.1.30.5sdsADCinputsIMCO-LS110-MIB
1.3.6.1.4.1.33283.1.30.5.1sdsADCitem0IMCO-LS110-MIB
1.3.6.1.4.1.33283.1.30.5.1.3sdsTempSensValueIMCO-LS110-MIB