IEEE8021-PSFP-MIB :: ieee8021PSFPMatchingFramesCount

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsIEEE8021-PSFP-MIBieee8021PSFPMatchingFramesCount

ieee8021PSFPMatchingFramesCount

Module: IEEE8021-PSFP-MIB

OID (symbolic): IEEE8021-PSFP-MIB::ieee8021PSFPMatchingFramesCount

OID (numeric): 1.3.111.2.802.1.1.31.1.1.1.1.6

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The MatchingFramesCount counter counts received frames that match this stream filter.

What is ieee8021PSFPMatchingFramesCount?

A running count of received frames that matched this stream filter's stream handle and priority criteria, regardless of whether they were ultimately passed by the gate. An operator monitoring TSN traffic compares this to the passing/not-passing counters to gauge how much traffic each filter is seeing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.31.1.1.1.1.6
snmpwalk -v2c -c public <target> IEEE8021-PSFP-MIB::ieee8021PSFPMatchingFramesCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.111.2.802.1.1.31.1.1.1.1.6.1
snmpget -v2c -c public <target> IEEE8021-PSFP-MIB::ieee8021PSFPMatchingFramesCount.1

Start monitoring Vendor-neutral IEEE 802.1Qci standard (TSN-capable Ethernet bridge or switch) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEEE8021-PSFP-MIB::ieee8021PSFPMatchingFramesCount OID value, configure state conditions and alerts, and monitor any Vendor-neutral IEEE 802.1Qci standard (TSN-capable Ethernet bridge or switch) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing IEEE8021-PSFP-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ieee8021PSFPMatchingFramesCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The MatchingFramesCount counter counts received frames that match this stream filter. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (3 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.111.2.802.1.1ieee802dot1mibsIEEE8021-TC-MIB
Numeric OIDNameModule
1.3.111.2.802.1.1.31ieee8021PSFPMibIEEE8021-PSFP-MIB
1.3.111.2.802.1.1.31.1ieee8021PSFPObjectsIEEE8021-PSFP-MIB
1.3.111.2.802.1.1.31.1.1ieee8021PSFPStreamFilterParametersIEEE8021-PSFP-MIB
1.3.111.2.802.1.1.31.1.1.1ieee8021PSFPStreamFilterTableIEEE8021-PSFP-MIB
1.3.111.2.802.1.1.31.1.1.1.1ieee8021PSFPStreamFilterEntryIEEE8021-PSFP-MIB
1.3.111.2.802.1.1.31.1.1.1.1.6ieee8021PSFPMatchingFramesCountIEEE8021-PSFP-MIB