All MIBs › IEEE8021-PSFP-MIB › ieee8021PSFPGateClosedDueToOctetsExceeded
ieee8021PSFPGateClosedDueToOctetsExceeded
Module: IEEE8021-PSFP-MIB
OID (symbolic): IEEE8021-PSFP-MIB::ieee8021PSFPGateClosedDueToOctetsExceeded
OID (numeric): 1.3.111.2.802.1.1.31.1.2.1.1.29
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-create
Description: The PSFPGateClosedDueToOctetsExceeded parameter contains a Boolean value that indicates whether, if the PSFPGateClosedDueToOctetsExceeded function is enabled, all frames are to be discarded (TRUE) or not (FALSE).
The value of this object MUST be retained across reinitializations of the management system.
What is ieee8021PSFPGateClosedDueToOctetsExceeded?
When the octets-exceeded-closing function is enabled, this boolean shows (TRUE) that the gate is currently forced closed because a gate-open interval's byte budget was exceeded, or (FALSE) that it's operating normally.
OID Breakdown
Upper-level ancestors (3 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.111.2.802.1.1 | ieee802dot1mibs | IEEE8021-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.111.2.802.1.1.31 | ieee8021PSFPMib | IEEE8021-PSFP-MIB |
| 1.3.111.2.802.1.1.31.1 | ieee8021PSFPObjects | IEEE8021-PSFP-MIB |
| 1.3.111.2.802.1.1.31.1.2 | ieee8021PSFPStreamGateParameters | IEEE8021-PSFP-MIB |
| 1.3.111.2.802.1.1.31.1.2.1 | ieee8021PSFPStreamGateTable | IEEE8021-PSFP-MIB |
| 1.3.111.2.802.1.1.31.1.2.1.1 | ieee8021PSFPStreamGateEntry | IEEE8021-PSFP-MIB |
| 1.3.111.2.802.1.1.31.1.2.1.1.29 | ieee8021PSFPGateClosedDueToOctetsExceeded | IEEE8021-PSFP-MIB |