IEEE8021-PE-MIB :: ieee8021BridgePEPortRxrqErrorsBridge

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IEEE8021-PE-MIB › ieee8021BridgePEPortRxrqErrorsBridge

ieee8021BridgePEPortRxrqErrorsBridge

Module: IEEE8021-PE-MIB

OID (symbolic): IEEE8021-PE-MIB::ieee8021BridgePEPortRxrqErrorsBridge

OID (numeric): 1.3.111.2.802.1.1.25.2.1.1.8

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of PE CSP flow control overflow errors that have occured for requests on the Bridge.

What is ieee8021BridgePEPortRxrqErrorsBridge?

A read-only 64-bit counter (in frames) of PE Control and Status Protocol (CSP) flow control overflow errors that occurred for requests on the Bridge side of this port. A climbing count indicates the Bridge is overwhelming the CSP control channel with requests faster than it can be serviced.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.25.2.1.1.8
snmpwalk -v2c -c public <target> IEEE8021-PE-MIB::ieee8021BridgePEPortRxrqErrorsBridge

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.111.2.802.1.1.25.2.1.1.8.1
snmpget -v2c -c public <target> IEEE8021-PE-MIB::ieee8021BridgePEPortRxrqErrorsBridge.1

Start monitoring Vendor-neutral IEEE 802.1BR standard (port extender/fabric extender and controlling bridge) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEEE8021-PE-MIB::ieee8021BridgePEPortRxrqErrorsBridge OID value, configure state conditions and alerts, and monitor any Vendor-neutral IEEE 802.1BR standard (port extender/fabric extender and controlling bridge) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing IEEE8021-PE-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ieee8021BridgePEPortRxrqErrorsBridge into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of PE CSP flow control overflow errors that have occured for requests on the Bridge. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (3 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.111.2.802.1.1ieee802dot1mibsIEEE8021-TC-MIB
Numeric OIDNameModule
1.3.111.2.802.1.1.25ieee8021BridgePEMibIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2ieee8021BridgePEObjectsIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1ieee8021BridgePEPortTableIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1.1ieee8021BridgePEPortEntryIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1.1.8ieee8021BridgePEPortRxrqErrorsBridgeIEEE8021-PE-MIB