IEEE8021-PE-MIB :: ieee8021BridgePECounterDiscontinuityTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IEEE8021-PE-MIB › ieee8021BridgePECounterDiscontinuityTime

ieee8021BridgePECounterDiscontinuityTime

Module: IEEE8021-PE-MIB

OID (symbolic): IEEE8021-PE-MIB::ieee8021BridgePECounterDiscontinuityTime

OID (numeric): 1.3.111.2.802.1.1.25.2.1.1.7

Node type: OBJECT-TYPE

Type: TimeStamp

Access: read-only

Description: The value of sysUpTime on the most recent occasion at which any one or more of the counters in this conceptaul row suffered a discontinuity. The relevant counters are the specific instances associated with this conceptual row of any Counter32 or Counter64 object. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value.

What is ieee8021BridgePECounterDiscontinuityTime?

A read-only timestamp (sysUpTime value) marking the last time any of this row's Counter32/Counter64 statistics had a discontinuity, such as a reset; zero if none occurred since the management subsystem last restarted. An admin checks this before trusting a delta calculated between two counter polls, since a discontinuity would make that delta meaningless.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.25.2.1.1.7
snmpwalk -v2c -c public <target> IEEE8021-PE-MIB::ieee8021BridgePECounterDiscontinuityTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.111.2.802.1.1.25.2.1.1.7.1
snmpget -v2c -c public <target> IEEE8021-PE-MIB::ieee8021BridgePECounterDiscontinuityTime.1

Start monitoring Vendor-neutral IEEE 802.1BR standard (port extender/fabric extender and controlling bridge) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEEE8021-PE-MIB::ieee8021BridgePECounterDiscontinuityTime OID value, configure state conditions and alerts, and monitor any Vendor-neutral IEEE 802.1BR standard (port extender/fabric extender and controlling bridge) from a single console.

OID Breakdown

Upper-level ancestors (3 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.111.2.802.1.1ieee802dot1mibsIEEE8021-TC-MIB
Numeric OIDNameModule
1.3.111.2.802.1.1.25ieee8021BridgePEMibIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2ieee8021BridgePEObjectsIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1ieee8021BridgePEPortTableIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1.1ieee8021BridgePEPortEntryIEEE8021-PE-MIB
1.3.111.2.802.1.1.25.2.1.1.7ieee8021BridgePECounterDiscontinuityTimeIEEE8021-PE-MIB