IEEE8021-CN-MIB :: ieee8021CnRpPortPriMaxRps

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › IEEE8021-CN-MIB › ieee8021CnRpPortPriMaxRps

ieee8021CnRpPortPriMaxRps

Module: IEEE8021-CN-MIB

OID (symbolic): IEEE8021-CN-MIB::ieee8021CnRpPortPriMaxRps

OID (numeric): 1.3.111.2.802.1.1.18.1.7.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: An integer controlling the maximum number of Reaction Points allowed for this CNPV on this Port. An end station SHALL not create more than this many Reaction Point on this Port, but it MAY create fewer.

What is ieee8021CnRpPortPriMaxRps?

Caps how many Reaction Points this port is allowed to create for this CNPV; the end station won't create more RPs than this limit but may create fewer, so raising it allows more concurrent rate-limited flows for a given priority on that port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.18.1.7.1.4
snmpwalk -v2c -c public <target> IEEE8021-CN-MIB::ieee8021CnRpPortPriMaxRps

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.111.2.802.1.1.18.1.7.1.4.1
snmpget -v2c -c public <target> IEEE8021-CN-MIB::ieee8021CnRpPortPriMaxRps.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.111.2.802.1.1.18.1.7.1.4.1 i <value>

Start monitoring data center Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IEEE8021-CN-MIB::ieee8021CnRpPortPriMaxRps OID value, configure state conditions and alerts, and monitor any data center Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (3 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.111.2.802.1.1ieee802dot1mibsIEEE8021-TC-MIB
Numeric OIDNameModule
1.3.111.2.802.1.1.18ieee8021CnMibIEEE8021-CN-MIB
1.3.111.2.802.1.1.18.1ieee8021CnMIBObjectsIEEE8021-CN-MIB
1.3.111.2.802.1.1.18.1.7ieee8021CnRpPortPriTableIEEE8021-CN-MIB
1.3.111.2.802.1.1.18.1.7.1ieee8021CnRpPortPriEntryIEEE8021-CN-MIB
1.3.111.2.802.1.1.18.1.7.1.4ieee8021CnRpPortPriMaxRpsIEEE8021-CN-MIB