All MIBs › IBMNETU-MIB › ibmnetuPCIAdapOperStatus
ibmnetuPCIAdapOperStatus
Module: IBMNETU-MIB
OID (symbolic): IBMNETU-MIB::ibmnetuPCIAdapOperStatus
OID (numeric): 1.3.6.1.4.1.2.6.150.3.1.1.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The operational status of this PCI adapter.
unknown (1) : If there was problem determining the operational status of the adapter.
not-configured (2) : If the adapter inserted in the slot is recognized but no router configuration exists.
not-present (3) : If no adapter is currently inserted.
does-not-apply (4) : If this adapter does not contain an operational state.
enable-pending (5) : If commands have been issued to enable the adapter but have not been completed.
enabled (6) : If commands have been successfully issued to enable the adapter.
disable-pending (7) : If commands have been issued to disable the adapter but have not been completed.
disabled (8) : If commands have been successfully issued to disable the adapter.
not-initialized (9) : If the adapter has not completed its initialization.
unknown-device (10) : If the adapter inserted in the slot can not be recognized.
hardware-error (11) : If the adapter can not be used nor made ready to be used.
not-powered (12) : If the adapter has had a problem obtaining power from its slot.
diagnostics (13) : If the adapter is currently undergoing diagnostics.
wrs-available (14) : If the adapter is currently configured and available for WAN restoral.
mis-configured (15) : If the adapter is inserted in the slot but the router configuration is of a different type.
What is ibmnetuPCIAdapOperStatus?
This read-only INTEGER reports the operational status of a PCI adapter, covering states from not-present and not-configured through enabled, disabled, hardware-error, and mis-configured, among others. Admins check this to diagnose why a specific adapter isn't functioning, distinguishing hardware faults from configuration mismatches. Seeing mis-configured(15) would tell an admin the physical adapter type doesn't match the router's configuration for that slot, while hardware-error(11) points to a defective card.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.6.150.3.1.1.1.3 snmpwalk -v2c -c public <target> IBMNETU-MIB::ibmnetuPCIAdapOperStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2.6.150.3.1.1.1.3.1 snmpget -v2c -c public <target> IBMNETU-MIB::ibmnetuPCIAdapOperStatus.1
Start monitoring IBM NetVista U workstation/thin client with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IBMNETU-MIB::ibmnetuPCIAdapOperStatus OID value, configure state conditions and alerts, and monitor any IBM NetVista U workstation/thin client from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2 | ibm | ATM-ADAPTER-MIB |
| 1.3.6.1.4.1.2.6 | ibmProd | ATM-ADAPTER-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2.6.150 | ibmnetu | IBMNETU-MIB |
| 1.3.6.1.4.1.2.6.150.3 | ibmnetuhardware | IBMNETU-MIB |
| 1.3.6.1.4.1.2.6.150.3.1 | ibmnetuhardwareGeneral | IBMNETU-MIB |
| 1.3.6.1.4.1.2.6.150.3.1.1 | ibmnetuPCIAdapTable | IBMNETU-MIB |
| 1.3.6.1.4.1.2.6.150.3.1.1.1 | ibmnetuPCIAdapEntry | IBMNETU-MIB |
| 1.3.6.1.4.1.2.6.150.3.1.1.1.3 | ibmnetuPCIAdapOperStatus | IBMNETU-MIB |