HYTERA-REPEATER-MIB :: rptForbid

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › HYTERA-REPEATER-MIB › rptForbid

rptForbid

Module: HYTERA-REPEATER-MIB

OID (symbolic): HYTERA-REPEATER-MIB::rptForbid

OID (numeric): 1.3.6.1.4.1.40297.1.2.2.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The status of the repeater's all function. nomal(0), forbid(1). If the repeater is forbided, you can only wake up it by setting the rptRadioStatus object to 0 in local RDAC model.

What is rptForbid?

A stronger version of rptKnockdown that disables all of the repeater's functions, not just repeating: normal(0) or forbid(1); once forbidden, the unit can only be woken again by setting rptRadioState to 0 locally via the RDAC configuration tool, so use with care.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.40297.1.2.2.11
snmpwalk -v2c -c public <target> HYTERA-REPEATER-MIB::rptForbid

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.40297.1.2.2.11.1
snmpget -v2c -c public <target> HYTERA-REPEATER-MIB::rptForbid.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.40297.1.2.2.11.1 i <value>

Start monitoring Hytera digital radio repeater with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HYTERA-REPEATER-MIB::rptForbid OID value, configure state conditions and alerts, and monitor any Hytera digital radio repeater from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.40297hyteraRepeaterMIBHYTERA-REPEATER-MIB
1.3.6.1.4.1.40297.1productHYTERA-REPEATER-MIB
1.3.6.1.4.1.40297.1.2repeaterHYTERA-REPEATER-MIB
1.3.6.1.4.1.40297.1.2.2rptControlHYTERA-REPEATER-MIB
1.3.6.1.4.1.40297.1.2.2.11rptForbidHYTERA-REPEATER-MIB