HWMUSA-SIGTRAN-MIB :: hwSctpGlobalStatAssocCurEstab

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HWMUSA-SIGTRAN-MIB › hwSctpGlobalStatAssocCurEstab

hwSctpGlobalStatAssocCurEstab

Module: HWMUSA-SIGTRAN-MIB

OID (symbolic): HWMUSA-SIGTRAN-MIB::hwSctpGlobalStatAssocCurEstab

OID (numeric): 1.3.6.1.4.1.2011.2.6.7.6.1.8.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of current associations

What is hwSctpGlobalStatAssocCurEstab?

The current number of established SCTP associations on this device, a quick health check of overall signaling connectivity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.2.6.7.6.1.8.1
snmpwalk -v2c -c public <target> HWMUSA-SIGTRAN-MIB::hwSctpGlobalStatAssocCurEstab

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.2.6.7.6.1.8.1.1
snmpget -v2c -c public <target> HWMUSA-SIGTRAN-MIB::hwSctpGlobalStatAssocCurEstab.1

Start monitoring Huawei SIGTRAN signaling gateway / media gateway controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HWMUSA-SIGTRAN-MIB::hwSctpGlobalStatAssocCurEstab OID value, configure state conditions and alerts, and monitor any Huawei SIGTRAN signaling gateway / media gateway controller from a single console.

How to Use in IPNetwork Monitor

Select a Huawei SIGTRAN signaling gateway / media gateway controller as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwSctpGlobalStatAssocCurEstab into the Find box to locate it in the OID tree, then select it and click OK. The number of current associations. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.2productsEXPERTV2-MIB
1.3.6.1.4.1.2011.2.6musaHUAWEI-MA5200-MIB
1.3.6.1.4.1.2011.2.6.7iasHUAWEI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.2.6.7.6hwIASSigtranHWMUSA-SIGTRAN-MIB
1.3.6.1.4.1.2011.2.6.7.6.1hwIASSigtranObjectsHWMUSA-SIGTRAN-MIB
1.3.6.1.4.1.2011.2.6.7.6.1.8hwSctpGlobalStatTableHWMUSA-SIGTRAN-MIB
1.3.6.1.4.1.2011.2.6.7.6.1.8.1hwSctpGlobalStatAssocCurEstabHWMUSA-SIGTRAN-MIB