HUAWEI-STACK-MIB :: hwCssPortInOctets

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-STACK-MIB › hwCssPortInOctets

hwCssPortInOctets

Module: HUAWEI-STACK-MIB

OID (symbolic): HUAWEI-STACK-MIB::hwCssPortInOctets

OID (numeric): 1.3.6.1.4.1.2011.5.25.183.3.4.1.9

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total number of octets received on the interface.

What is hwCssPortInOctets?

The total number of octets received on this CSS-connected port, a basic inbound-traffic-volume counter.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.5.25.183.3.4.1.9
snmpwalk -v2c -c public <target> HUAWEI-STACK-MIB::hwCssPortInOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.5.25.183.3.4.1.9.1
snmpget -v2c -c public <target> HUAWEI-STACK-MIB::hwCssPortInOctets.1

Start monitoring Huawei stackable switch, e.g. S-series (Cluster Switch System stacking) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-STACK-MIB::hwCssPortInOctets OID value, configure state conditions and alerts, and monitor any Huawei stackable switch, e.g. S-series (Cluster Switch System stacking) from a single console.

How to Use in IPNetwork Monitor

Select a Huawei stackable switch, e.g. S-serie (Cluster Switch System stacking) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwCssPortInOctets into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of octets received on the interface. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.5huaweiMgmtHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.5.25huaweiDatacommHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.5.25.183huaweiStackMIBHUAWEI-STACK-MIB
1.3.6.1.4.1.2011.5.25.183.3hwCssObjectHUAWEI-STACK-MIB
1.3.6.1.4.1.2011.5.25.183.3.4hwCssPortInfoTableHUAWEI-STACK-MIB
1.3.6.1.4.1.2011.5.25.183.3.4.1hwCssPortInfoEntryHUAWEI-STACK-MIB
1.3.6.1.4.1.2011.5.25.183.3.4.1.9hwCssPortInOctetsHUAWEI-STACK-MIB