HUAWEI-SITE-MONITOR-MIB :: hwAcInputOperStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-SITE-MONITOR-MIB › hwAcInputOperStatus

hwAcInputOperStatus

Module: HUAWEI-SITE-MONITOR-MIB

OID (symbolic): HUAWEI-SITE-MONITOR-MIB::hwAcInputOperStatus

OID (numeric): 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: State of the site AC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC distribution uint is in the normal state; If the enumeration value is 2, it indicates that AC distribution uint power off; If the enumeration value is 3, it indicates that AC input phase absent; If the enumeration value is 4, it indicates that AC voltage is over upper alarm threshold; If the enumeration value is 5, it indicates that AC voltage is under lower alarm threshold; If the enumeration value is 254, it indicates AC distribution uint alarm resume; If the enumeration value is 255, it indicates AC distribution uint operation status unknown.

What is hwAcInputOperStatus?

State of the site AC distribution uint. Coded values: 1=that the site AC distribution uint is in the normal state; 2=that AC distribution uint power off; 3=that AC input phase absent; 4=that AC voltage is over upper alarm threshold; 5=that AC voltage is under lower alarm threshold; 254=AC distribution uint alarm resume; 255=AC distribution uint operation status unknown. An NMS polls hwAcInputOperStatus to learn current equipment state without needing a separate alarm-table lookup.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99
snmpwalk -v2c -c public <target> HUAWEI-SITE-MONITOR-MIB::hwAcInputOperStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99.1
snmpget -v2c -c public <target> HUAWEI-SITE-MONITOR-MIB::hwAcInputOperStatus.1

Start monitoring Huawei multi-site management platform (load/backup/patch management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-SITE-MONITOR-MIB::hwAcInputOperStatus OID value, configure state conditions and alerts, and monitor any Huawei multi-site management platform (load/backup/patch management) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.164hwSiteMonitorMIBHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1hwSiteMonitorMIBObjectsHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1.5hwSiteAcDistributionsHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1.5.2hwAcDistributionHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1.5.2.1hwAcInputTableHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1.5.2.1.1hwAcInputEntryHUAWEI-SITE-MONITOR-MIB
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99hwAcInputOperStatusHUAWEI-SITE-MONITOR-MIB