Description: Number of received v0 gtpc packets.

What is hwGTPRcvV0GtpC?

Counts GTPv0 control-plane (GTP-C) packets received by the firewall's GTP inspection module; a nonzero, growing value confirms legacy GTPv0 signaling traffic is passing through this Eudemon/USG device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.122.35.1.1
snmpwalk -v2c -c public <target> HUAWEI-SECURITY-GTP-MIB::hwGTPRcvV0GtpC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.122.35.1.1.1
snmpget -v2c -c public <target> HUAWEI-SECURITY-GTP-MIB::hwGTPRcvV0GtpC.1

Start monitoring Huawei Eudemon firewall/USG security gateway (GTP mobile-tunnel inspection) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-SECURITY-GTP-MIB::hwGTPRcvV0GtpC OID value, configure state conditions and alerts, and monitor any Huawei Eudemon firewall/USG security gateway (GTP mobile-tunnel inspection) from a single console.

How to Use in IPNetwork Monitor

Select a Huawei Eudemon firewall/USG security gateway (GTP mobile-tunnel inspection) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwGTPRcvV0GtpC into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of received v0 gtpc packets. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.6.122hwSecurityHUAWEI-SECURITY-AAA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.122.35hwGTPHUAWEI-SECURITY-GTP-MIB
1.3.6.1.4.1.2011.6.122.35.1hwGTPStatsHUAWEI-SECURITY-GTP-MIB
1.3.6.1.4.1.2011.6.122.35.1.1hwGTPRcvV0GtpCHUAWEI-SECURITY-GTP-MIB