HUAWEI-CLOCK-MIB :: hwClockSrcCfgSsmTimeout

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-CLOCK-MIB › hwClockSrcCfgSsmTimeout

hwClockSrcCfgSsmTimeout

Module: HUAWEI-CLOCK-MIB

OID (symbolic): HUAWEI-CLOCK-MIB::hwClockSrcCfgSsmTimeout

OID (numeric): 1.3.6.1.4.1.2011.5.25.186.1.11.1.14

Node type: OBJECT-TYPE

Type: Integer32

Access: read-create

Description: Description.

What is hwClockSrcCfgSsmTimeout?

Sets how long (2000-32000, in milliseconds based on the value range) the device waits without a valid SSM update from this clock source before treating its SSM information as stale/invalid. (Note: the DESCRIPTION field in the source MIB is the unhelpful placeholder "Description."; this reading is inferred from the object's name, its bounded Integer32 range -- larger than and consistent with a timeout on top of the sibling hwClockSrcCfgSsmInterval polling interval -- and standard SSM aging behavior.)

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.5huaweiMgmtHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.5.25huaweiDatacommHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.5.25.186hwClockMIBHUAWEI-CLOCK-MIB
1.3.6.1.4.1.2011.5.25.186.1hwClockManageObjectsHUAWEI-CLOCK-MIB
1.3.6.1.4.1.2011.5.25.186.1.11hwClockSrcCfgTableHUAWEI-CLOCK-MIB
1.3.6.1.4.1.2011.5.25.186.1.11.1hwClockSrcCfgEntryHUAWEI-CLOCK-MIB
1.3.6.1.4.1.2011.5.25.186.1.11.1.14hwClockSrcCfgSsmTimeoutHUAWEI-CLOCK-MIB