HUAWEI-BTEST-MIB :: hwBTSSCqtOfflineReason

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHUAWEI-BTEST-MIBhwBTSSCqtOfflineReason

hwBTSSCqtOfflineReason

Module: HUAWEI-BTEST-MIB

OID (symbolic): HUAWEI-BTEST-MIB::hwBTSSCqtOfflineReason

OID (numeric): 1.3.6.1.4.1.2011.6.21.3.2.1.2.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: accessible-for-notify

Description: Cqt module offline reason. Options: 1. commFail(1) - CQT module communication fail. Resolving method:Check CQT module running normal 2. userReset(2) - User reset command

What is hwBTSSCqtOfflineReason?

Reports why the CQT (customer quality test) module went offline: commFail (communication with the module failed -- check that it's running normally) or userReset (an operator issued a reset command).

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.21hwTestHUAWEI-BTEST-MIB
1.3.6.1.4.1.2011.6.21.3hwBTestHUAWEI-BTEST-MIB
1.3.6.1.4.1.2011.6.21.3.2hwBTestTrapsHUAWEI-BTEST-MIB
1.3.6.1.4.1.2011.6.21.3.2.1hwBTestTrapVbOidsHUAWEI-BTEST-MIB
1.3.6.1.4.1.2011.6.21.3.2.1.2hwBTestVbOidsReasonHUAWEI-BTEST-MIB
1.3.6.1.4.1.2011.6.21.3.2.1.2.1hwBTSSCqtOfflineReasonHUAWEI-BTEST-MIB