HPN-ICF-VSAN-MIB :: hpnicfVsanDmRCFCnt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-VSAN-MIBhpnicfVsanDmRCFCnt

hpnicfVsanDmRCFCnt

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The times that local switch has participated in a RCF (Reconfigure Fabric) process in this VSAN.

What is hpnicfVsanDmRCFCnt?

This read-only counter tracks the number of times the local switch has participated in a RCF (Reconfigure Fabric) process within a specific VSAN (Virtual SAN). RCF is the mechanism for dynamically rebuilding the fabric topology. Operators monitor this to understand fabric reconfiguration frequency, which can indicate topology changes, switch failures, or instability in the SAN.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18
snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18.1
snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt.1

Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1hpnicfVsanDmConfigurationHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2hpnicfVsanDmTableHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1hpnicfVsanDmEntryHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18hpnicfVsanDmRCFCntHPN-ICF-VSAN-MIB