All MIBs › HPN-ICF-VSAN-MIB › hpnicfVsanDmRCFCnt
hpnicfVsanDmRCFCnt
Module: HPN-ICF-VSAN-MIB
OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The times that local switch has participated in a RCF (Reconfigure Fabric) process in this VSAN.
What is hpnicfVsanDmRCFCnt?
This read-only counter tracks the number of times the local switch has participated in a RCF (Reconfigure Fabric) process within a specific VSAN (Virtual SAN). RCF is the mechanism for dynamically rebuilding the fabric topology. Operators monitor this to understand fabric reconfiguration frequency, which can indicate topology changes, switch failures, or instability in the SAN.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18 snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18.1 snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt.1
Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmRCFCnt OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127 | hpnicfSan | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1 | hpnicfVsan | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1 | hpnicfVsanMibObjects | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1 | hpnicfVsanDmConfiguration | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2 | hpnicfVsanDmTable | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1 | hpnicfVsanDmEntry | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.18 | hpnicfVsanDmRCFCnt | HPN-ICF-VSAN-MIB |