All MIBs › HPN-ICF-VSAN-MIB › hpnicfVsanDmPrincipalSwRunPriority
hpnicfVsanDmPrincipalSwRunPriority
Module: HPN-ICF-VSAN-MIB
OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13
Node type: OBJECT-TYPE
Type: HpnicfFcDomainPriority
Access: read-only
Description: Indicates the running priority of the principal switch in this VSAN.
What is hpnicfVsanDmPrincipalSwRunPriority?
The running priority value of the current principal switch in this VSAN, useful for confirming why a particular switch won principal-switch election over others with different configured priorities.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13 snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13.1 snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority.1
Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127 | hpnicfSan | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1 | hpnicfVsan | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1 | hpnicfVsanMibObjects | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1 | hpnicfVsanDmConfiguration | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2 | hpnicfVsanDmTable | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1 | hpnicfVsanDmEntry | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13 | hpnicfVsanDmPrincipalSwRunPriority | HPN-ICF-VSAN-MIB |