HPN-ICF-VSAN-MIB :: hpnicfVsanDmPrincipalSwRunPriority

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-VSAN-MIBhpnicfVsanDmPrincipalSwRunPriority

hpnicfVsanDmPrincipalSwRunPriority

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13

Node type: OBJECT-TYPE

Type: HpnicfFcDomainPriority

Access: read-only

Description: Indicates the running priority of the principal switch in this VSAN.

What is hpnicfVsanDmPrincipalSwRunPriority?

The running priority value of the current principal switch in this VSAN, useful for confirming why a particular switch won principal-switch election over others with different configured priorities.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13
snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13.1
snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority.1

Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmPrincipalSwRunPriority OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1hpnicfVsanDmConfigurationHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2hpnicfVsanDmTableHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1hpnicfVsanDmEntryHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.13hpnicfVsanDmPrincipalSwRunPriorityHPN-ICF-VSAN-MIB