HPN-ICF-VSAN-MIB :: hpnicfVsanDmLocalSwRunPriority

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-VSAN-MIBhpnicfVsanDmLocalSwRunPriority

hpnicfVsanDmLocalSwRunPriority

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmLocalSwRunPriority

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.14

Node type: OBJECT-TYPE

Type: HpnicfFcDomainPriority

Access: read-only

Description: Indicates the running priority of the local switch in this VSAN.

What is hpnicfVsanDmLocalSwRunPriority?

This read-only object displays the current running priority value of the local switch within a Virtual Storage Area Network (VSAN) domain, used in domain master election protocols. The priority determines which switch becomes the domain master when multiple switches participate in the same VSAN fabric. Operators reference this value to understand the failover behavior and redundancy positioning of switches in their Fibre Channel fabric topology.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.14
snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmLocalSwRunPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.14.1
snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmLocalSwRunPriority.1

Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmLocalSwRunPriority OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1hpnicfVsanDmConfigurationHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2hpnicfVsanDmTableHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1hpnicfVsanDmEntryHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.14hpnicfVsanDmLocalSwRunPriorityHPN-ICF-VSAN-MIB