hpnicfVsanDmFabricChangeNotify

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmFabricChangeNotify

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.3.0.3

Node type: NOTIFICATION-TYPE

Description:

This event will be triggered if a switch sends or receives a Build Fabric (BF) or a Reconfigure Fabric (RCF) message in a VSAN.

The conditions a switch can receive or send a BF or a RCF are listed as follows: 1. Two isolated fabrics in a VSAN merge into one fabric. If the Domain ID lists do not overlap, the sent or received message is BF, other cases, it is RCF. 2. If an upstream principal link which connects to principal switch and other switches become disconnected, the sent or received message is BF. 3. A BF or RCF process is triggered manually by configuration.

The notification contains the index of the VSAN in which a BF or a RCF was sent or received.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' HPN-ICF-VSAN-MIB::hpnicfVsanDmFabricChangeNotify
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.3.0.3

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:59892->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (402164212) 46 days, 13:07:22.12
  SNMPv2-MIB::snmpTrapOID.0 = OID: HPN-ICF-VSAN-MIB::hpnicfVsanDmFabricChangeNotify

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.11hpDATAPROTECTOR-MIB
1.3.6.1.4.1.11.2nmDATAPROTECTOR-MIB
1.3.6.1.4.1.11.2.14icfHP-ICF
1.3.6.1.4.1.11.2.14.11hpicfObjectsHP-ICF
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.3hpnicfVsanDmNotificationsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.3.0hpnicfVsanDmNotificationPrefixHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.3.0.3hpnicfVsanDmFabricChangeNotifyHPN-ICF-VSAN-MIB