HPN-ICF-VSAN-MIB :: hpnicfVsanDmDomainIdTypeConfigured

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-VSAN-MIBhpnicfVsanDmDomainIdTypeConfigured

hpnicfVsanDmDomainIdTypeConfigured

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdTypeConfigured

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specifies the type of configured domain ID, which can be static type or preferred type.

What is hpnicfVsanDmDomainIdTypeConfigured?

Specifies whether the domain ID set in hpnicfVsanDmDomainIdConfigured is 'static' (the switch insists on exactly that ID) or 'preferred' (the switch will accept a different ID assigned by the principal switch), defaulting to preferred. Admins use static type when a domain ID must never silently change during fabric reconfiguration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.6
snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdTypeConfigured

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.6.1
snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdTypeConfigured.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.6.1 i <value>

Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdTypeConfigured OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1hpnicfVsanDmConfigurationHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2hpnicfVsanDmTableHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1hpnicfVsanDmEntryHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.6hpnicfVsanDmDomainIdTypeConfiguredHPN-ICF-VSAN-MIB