All MIBs › HPN-ICF-VSAN-MIB › hpnicfVsanDmDomainIdConfigured
hpnicfVsanDmDomainIdConfigured
Module: HPN-ICF-VSAN-MIB
OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdConfigured
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.5
Node type: OBJECT-TYPE
Type: HpnicfFcDomainIdOrZero
Access: read-write
Description: Used to configure or cancel a domain ID for a switch in this VSAN.
When this value is not zero, the domain ID type should be specified together via hpnicfVsanDmDomainIdTypeConfigured, or the default value of preferred type will be taken. The zero value is used to cancel the domain ID configured, and then, there is no need to specify its type.
When statically build a fabric, the configured domain ID is the actual domain ID of the switch. If this object is not manually configured, the switch will isolate all of its E_ports in this VSAN no matter what domain ID type is configured.
When dynamically build a fabric, the configured domain ID is desired by the switch, but the domain ID assigned to the switch may not be the desired one. If a non-principal switch fails to obtain any domain ID from the principal switch, the non-principal switch will isolate the upstream link. If a non-principal switch obtains a domain ID from the principal switch other than the desired one, different actions will be taken according to different domain ID type configured: - If configured static type, The non-principal switch will isolate the upstream link and refuse other domain IDs assigned by the principal switch. - If configured preferred type, the non-principal switch will use the domain ID assigned by the principal switch.
What is hpnicfVsanDmDomainIdConfigured?
Configures (or, when set to zero, cancels) the domain ID a switch wants to use in this VSAN; its interpretation depends on hpnicfVsanDmDomainIdTypeConfigured and on whether the fabric is built statically or dynamically -- e.g. a switch configured for 'static' type will isolate its upstream link rather than accept a different domain ID assigned by the principal switch.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.5 snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdConfigured
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.5.1 snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdConfigured.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.5.1 s <value>
Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdConfigured OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127 | hpnicfSan | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1 | hpnicfVsan | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1 | hpnicfVsanMibObjects | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1 | hpnicfVsanDmConfiguration | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2 | hpnicfVsanDmTable | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1 | hpnicfVsanDmEntry | HPN-ICF-VSAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.5 | hpnicfVsanDmDomainIdConfigured | HPN-ICF-VSAN-MIB |