HPN-ICF-VSAN-MIB :: hpnicfVsanDmDomainIdAssigned

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-VSAN-MIBhpnicfVsanDmDomainIdAssigned

hpnicfVsanDmDomainIdAssigned

Module: HPN-ICF-VSAN-MIB

OID (symbolic): HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdAssigned

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.10

Node type: OBJECT-TYPE

Type: HpnicfFcDomainIdOrZero

Access: read-only

Description: Indicates the Domain ID of the local switch in this VSAN or zero if no Domain ID has been assigned.

What is hpnicfVsanDmDomainIdAssigned?

The domain ID actually assigned to the local switch in this VSAN, or zero if none has been assigned yet. Admins check this after a fabric build to confirm the switch obtained a valid domain ID rather than being isolated.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.10
snmpwalk -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdAssigned

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.10.1
snmpget -v2c -c public <target> HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdAssigned.1

Start monitoring HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-VSAN-MIB::hpnicfVsanDmDomainIdAssigned OID value, configure state conditions and alerts, and monitor any HP Fibre Channel SAN switch (e.g. HPE FlexFabric 5945 Switch Series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.1hpnicfVsanHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1hpnicfVsanMibObjectsHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1hpnicfVsanDmConfigurationHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2hpnicfVsanDmTableHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1hpnicfVsanDmEntryHPN-ICF-VSAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.1.1.1.2.1.10hpnicfVsanDmDomainIdAssignedHPN-ICF-VSAN-MIB