All MIBs › HPN-ICF-RMON-EXT-MIB › hpnicfprialarmVariable
hpnicfprialarmVariable
Module: HPN-ICF-RMON-EXT-MIB
OID (symbolic): HPN-ICF-RMON-EXT-MIB::hpnicfprialarmVariable
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.3
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe.
During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4).
This object may not be modified if the associated alarmStatus object is equal to valid(1).
What is hpnicfprialarmVariable?
This read-write string is the object identifier of the specific device variable to be sampled by this alarm, restricted to ASN.1 primitive integer types (INTEGER, Counter32, Counter64, Gauge, or TimeTicks), and cannot be modified while the entry's status is valid(1); if the named variable becomes unavailable, the entry's status automatically changes to invalid(4). An admin points this at the exact MIB variable whose value should trigger rising/falling threshold alarms, such as an interface error counter or CPU utilization gauge. For example, setting hpnicfprialarmVariable to an interface's error counter OID makes this alarm entry track that counter against its configured thresholds.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.3 snmpwalk -v2c -c public <target> HPN-ICF-RMON-EXT-MIB::hpnicfprialarmVariable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.3.1 snmpget -v2c -c public <target> HPN-ICF-RMON-EXT-MIB::hpnicfprialarmVariable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.3.1 s <value>
Start monitoring HP/H3C Comware switch or router (extended RMON-style alarms) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-RMON-EXT-MIB::hpnicfprialarmVariable OID value, configure state conditions and alerts, and monitor any HP/H3C Comware switch or router (extended RMON-style alarms) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.8 | hpnicfRhw | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.8.4 | hpnicfrmonExtend | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.8.4.4 | hpnicfperformance | HPN-ICF-RMON-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1 | hpnicfprialarmTable | HPN-ICF-RMON-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1 | hpnicfprialarmEntry | HPN-ICF-RMON-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.3 | hpnicfprialarmVariable | HPN-ICF-RMON-EXT-MIB |