All MIBs › HPN-ICF-RDDC-MIB › hpnicfRddcPreempTimeRemain
hpnicfRddcPreempTimeRemain
Module: HPN-ICF-RDDC-MIB
OID (symbolic): HPN-ICF-RDDC-MIB::hpnicfRddcPreempTimeRemain
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1.1.3
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: The redundancy group should not switch back immediately when a failover is recovered. The preempt delay timer is started for waiting the failover became believable. This object contains the current preempt delay time remained when a failover is recovered.
What is hpnicfRddcPreempTimeRemain?
This read-only value, in minutes, reports how much longer the preempt delay timer has left to run after a failed component in this redundancy group has recovered, before the group is allowed to switch back. Admins check it to know how soon an automatic switchback will occur following a recovery, since the group deliberately waits to confirm the recovery is stable before reverting. For example, hpnicfRddcPreempTimeRemain reading 3 tells the admin this redundancy group will wait 3 more minutes before switching back to the recovered primary path.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1.1.3 snmpwalk -v2c -c public <target> HPN-ICF-RDDC-MIB::hpnicfRddcPreempTimeRemain
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1.1.3.1 snmpget -v2c -c public <target> HPN-ICF-RDDC-MIB::hpnicfRddcPreempTimeRemain.1
Start monitoring HP Networking (H3C-derived) IRF stacking equipment (redundancy group failover) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-RDDC-MIB::hpnicfRddcPreempTimeRemain OID value, configure state conditions and alerts, and monitor any HP Networking (H3C-derived) IRF stacking equipment (redundancy group failover) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.151 | hpnicfRddc | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.151.1 | hpnicfRddcObjects | HPN-ICF-RDDC-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1 | hpnicfRddcInfo | HPN-ICF-RDDC-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1 | hpnicfRddcTable | HPN-ICF-RDDC-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1.1 | hpnicfRddcEntry | HPN-ICF-RDDC-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.151.1.1.1.1.3 | hpnicfRddcPreempTimeRemain | HPN-ICF-RDDC-MIB |