HPN-ICF-IPX-MIB :: hpnicfIpxStatTotalReceives

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HPN-ICF-IPX-MIB › hpnicfIpxStatTotalReceives

hpnicfIpxStatTotalReceives

Module: HPN-ICF-IPX-MIB

OID (symbolic): HPN-ICF-IPX-MIB::hpnicfIpxStatTotalReceives

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.34.4.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of packets received.

What is hpnicfIpxStatTotalReceives?

The total number of IPX packets received by this device across all interfaces, the top-level inbound counter to check first before drilling into the more specific error and protocol counters in this table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.34.4.1.1
snmpwalk -v2c -c public <target> HPN-ICF-IPX-MIB::hpnicfIpxStatTotalReceives

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.34.4.1.1.1
snmpget -v2c -c public <target> HPN-ICF-IPX-MIB::hpnicfIpxStatTotalReceives.1

Start monitoring HP/H3C Comware routers and switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-IPX-MIB::hpnicfIpxStatTotalReceives OID value, configure state conditions and alerts, and monitor any HP/H3C Comware routers and switches from a single console.

How to Use in IPNetwork Monitor

Select an HP/H3C Comware router or switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpnicfIpxStatTotalReceives into the Find box to locate it in the OID tree, then select it and click OK. The total number of packets received. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.34hpnicfIpxHPN-ICF-IPX-MIB
1.3.6.1.4.1.11.2.14.11.15.2.34.4hpnicfIpxStatHPN-ICF-IPX-MIB
1.3.6.1.4.1.11.2.14.11.15.2.34.4.1hpnicfIpxStatGlobalHPN-ICF-IPX-MIB
1.3.6.1.4.1.11.2.14.11.15.2.34.4.1.1hpnicfIpxStatTotalReceivesHPN-ICF-IPX-MIB