hpnicfIPSecGlobalNoFindSaDropPkts

Module: HPN-ICF-IPSEC-MONITOR-MIB

OID (symbolic): HPN-ICF-IPSEC-MONITOR-MIB::hpnicfIPSecGlobalNoFindSaDropPkts

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.7.1.5.16

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of packets dropped due to not find SA by all current and previous IPSec Phase-2 Tunnels.

What is hpnicfIPSecGlobalNoFindSaDropPkts?

The device-wide total of packets dropped because no matching security association could be found, across all IPSec tunnels. A spike often coincides with SA table churn during mass rekeys or after a configuration change that removed policies still receiving traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.7.1.5.16
snmpwalk -v2c -c public <target> HPN-ICF-IPSEC-MONITOR-MIB::hpnicfIPSecGlobalNoFindSaDropPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.7.1.5.16.1
snmpget -v2c -c public <target> HPN-ICF-IPSEC-MONITOR-MIB::hpnicfIPSecGlobalNoFindSaDropPkts.1

Start monitoring HP/Comware VPN router/security gateway (IPsec tunnel statistics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-IPSEC-MONITOR-MIB::hpnicfIPSecGlobalNoFindSaDropPkts OID value, configure state conditions and alerts, and monitor any HP/Comware VPN router/security gateway (IPsec tunnel statistics) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.7hpnicfIPSecMonitorHPN-ICF-IPSEC-MONITOR-MIB
1.3.6.1.4.1.11.2.14.11.15.2.7.1hpnicfIPSecObjectsHPN-ICF-IPSEC-MONITOR-MIB
1.3.6.1.4.1.11.2.14.11.15.2.7.1.5hpnicfIPSecGlobalStatsHPN-ICF-IPSEC-MONITOR-MIB
1.3.6.1.4.1.11.2.14.11.15.2.7.1.5.16hpnicfIPSecGlobalNoFindSaDropPktsHPN-ICF-IPSEC-MONITOR-MIB