HPN-ICF-FC-ZONE-SERVER-MIB :: hpnicfFcZsMergeFailedEnable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-FC-ZONE-SERVER-MIBhpnicfFcZsMergeFailedEnable

hpnicfFcZsMergeFailedEnable

Module: HPN-ICF-FC-ZONE-SERVER-MIB

OID (symbolic): HPN-ICF-FC-ZONE-SERVER-MIB::hpnicfFcZsMergeFailedEnable

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Indicates whether the module will generate traps for Zone merge failure events.

What is hpnicfFcZsMergeFailedEnable?

A TruthValue that enables or disables sending the hpnicfFcZsMergeFailedNotify trap whenever a Zone merge with another switch fails. Admins enable this to get proactive alerts on fabric-merge problems rather than discovering them via polling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1.3
snmpwalk -v2c -c public <target> HPN-ICF-FC-ZONE-SERVER-MIB::hpnicfFcZsMergeFailedEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1.3.1
snmpget -v2c -c public <target> HPN-ICF-FC-ZONE-SERVER-MIB::hpnicfFcZsMergeFailedEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1.3.1 s <value>

Start monitoring HP/H3C Comware Fibre Channel SAN switch (FC zoning) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FC-ZONE-SERVER-MIB::hpnicfFcZsMergeFailedEnable OID value, configure state conditions and alerts, and monitor any HP/H3C Comware Fibre Channel SAN switch (FC zoning) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.9hpnicfFcZoneServerHPN-ICF-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.9.1hpnicfFcZoneMibObjectsHPN-ICF-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4hpnicfFcZsNotificationHPN-ICF-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1hpnicfFcZsNotificationSwitchHPN-ICF-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.9.1.4.1.3hpnicfFcZsMergeFailedEnableHPN-ICF-FC-ZONE-SERVER-MIB