All MIBs › HPN-ICF-FC-PING-MIB › hpnicfFcPingMaxTime
hpnicfFcPingMaxTime
Module: HPN-ICF-FC-PING-MIB
OID (symbolic): HPN-ICF-FC-PING-MIB::hpnicfFcPingMaxTime
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1.1.5
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: The maximum round trip time of all the packets that have been sent in this sequence.
What is hpnicfFcPingMaxTime?
This read-only value, in microseconds, reports the maximum round-trip time observed among all packets sent in this ping sequence. An admin compares it to the minimum and average times to gauge jitter or occasional latency spikes on the path. For example, a maximum time much higher than the average suggests intermittent congestion or a transient fabric issue affecting some packets but not others.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1.1.5 snmpwalk -v2c -c public <target> HPN-ICF-FC-PING-MIB::hpnicfFcPingMaxTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1.1.5.1 snmpget -v2c -c public <target> HPN-ICF-FC-PING-MIB::hpnicfFcPingMaxTime.1
Start monitoring HP/H3C Comware Fibre Channel switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FC-PING-MIB::hpnicfFcPingMaxTime OID value, configure state conditions and alerts, and monitor any HP/H3C Comware Fibre Channel switches from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127 | hpnicfSan | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5 | hpnicfFcPing | HPN-ICF-FC-PING-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1 | hpnicfFcPingObjects | HPN-ICF-FC-PING-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2 | hpnicfFcPingStatistics | HPN-ICF-FC-PING-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1 | hpnicfFcPingStatTable | HPN-ICF-FC-PING-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1.1 | hpnicfFcPingStatEntry | HPN-ICF-FC-PING-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.5.1.2.1.1.5 | hpnicfFcPingMaxTime | HPN-ICF-FC-PING-MIB |