HPN-ICF-FC-NAME-SERVER-MIB :: hpnicfFcNsPortLogoutNotifyEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HPN-ICF-FC-NAME-SERVER-MIB › hpnicfFcNsPortLogoutNotifyEnable

hpnicfFcNsPortLogoutNotifyEnable

Module: HPN-ICF-FC-NAME-SERVER-MIB

OID (symbolic): HPN-ICF-FC-NAME-SERVER-MIB::hpnicfFcNsPortLogoutNotifyEnable

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1.2

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: This object is used to determine whether hpnicfFcNsPortLogoutNotify will be generated for Nx_Port locally logging out.

What is hpnicfFcNsPortLogoutNotifyEnable?

This setting controls whether the switch sends an SNMP notification whenever a local Nx_Port logs out of the Fibre Channel fabric, the counterpart to the login-notification setting. Administrators enable it to catch unexpected device disconnections from the SAN fabric, which could indicate a cable pull, device failure, or planned maintenance. For example, enabling this would let a SAN admin get an immediate alert if a critical storage array's port unexpectedly logs out of the fabric.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1.2
snmpwalk -v2c -c public <target> HPN-ICF-FC-NAME-SERVER-MIB::hpnicfFcNsPortLogoutNotifyEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1.2.1
snmpget -v2c -c public <target> HPN-ICF-FC-NAME-SERVER-MIB::hpnicfFcNsPortLogoutNotifyEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1.2.1 s <value>

Start monitoring HP Networking Fibre Channel SAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FC-NAME-SERVER-MIB::hpnicfFcNsPortLogoutNotifyEnable OID value, configure state conditions and alerts, and monitor any HP Networking Fibre Channel SAN switches from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127hpnicfSanHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.127.10hpnicfFcNameServerHPN-ICF-FC-NAME-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.10.1hpnicfFcNameServerMibObjectsHPN-ICF-FC-NAME-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1hpnicfFcNsNotificationHPN-ICF-FC-NAME-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1hpnicfFcNsNotificationSwitchHPN-ICF-FC-NAME-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.127.10.1.1.1.2hpnicfFcNsPortLogoutNotifyEnableHPN-ICF-FC-NAME-SERVER-MIB