All MIBs › HPN-ICF-FC-FLOGIN-MIB › hpnicfFcFLoginClass2RxMTU
hpnicfFcFLoginClass2RxMTU
Module: HPN-ICF-FC-FLOGIN-MIB
OID (symbolic): HPN-ICF-FC-FLOGIN-MIB::hpnicfFcFLoginClass2RxMTU
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1.1.7
Node type: OBJECT-TYPE
Type: HpnicfFcRxMTU
Access: read-only
Description: The object specifies the Maximum Transmission Unit of an Fibre Channel frame that can be received by the logged-in Nx_Port in Class 2 service.
What is hpnicfFcFLoginClass2RxMTU?
This object is a read-only HpnicfFcRxMTU specifying the maximum transmission unit, in Class 2 service, that the logged-in Nx_Port can receive. It lets an administrator confirm what frame size a connected device supports for Class 2 (acknowledged) traffic, useful when troubleshooting frame-size mismatches. For example, it might report 2048 bytes as the Class 2 receive MTU negotiated during fabric login.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1.1.7 snmpwalk -v2c -c public <target> HPN-ICF-FC-FLOGIN-MIB::hpnicfFcFLoginClass2RxMTU
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1.1.7.1 snmpget -v2c -c public <target> HPN-ICF-FC-FLOGIN-MIB::hpnicfFcFLoginClass2RxMTU.1
Start monitoring HP/H3C Comware Fibre Channel switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FC-FLOGIN-MIB::hpnicfFcFLoginClass2RxMTU OID value, configure state conditions and alerts, and monitor any HP/H3C Comware Fibre Channel switches from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127 | hpnicfSan | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.127.3 | hpnicfFcFLogin | HPN-ICF-FC-FLOGIN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1 | hpnicfFcFLoginMibObjects | HPN-ICF-FC-FLOGIN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1 | hpnicfFcFLoginTable | HPN-ICF-FC-FLOGIN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1.1 | hpnicfFcFLoginEntry | HPN-ICF-FC-FLOGIN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.127.3.1.1.1.7 | hpnicfFcFLoginClass2RxMTU | HPN-ICF-FC-FLOGIN-MIB |