HPN-ICF-EPON-UNI-MIB :: hpnicfEponUniVCTCableLength

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HPN-ICF-EPON-UNI-MIB › hpnicfEponUniVCTCableLength

hpnicfEponUniVCTCableLength

Module: HPN-ICF-EPON-UNI-MIB

OID (symbolic): HPN-ICF-EPON-UNI-MIB::hpnicfEponUniVCTCableLength

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.33

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Get the cable length. When hpnicfEponUniVCTCableStatus is normal, the node stands for the length from the UNI port to the port opposite. When hpnicfEponUniVCTCableStatus is abnormal, it stands for the lengh from the UNI port to the failure place. Unit:meter(m).

What is hpnicfEponUniVCTCableLength?

The cable length in meters measured by the virtual cable test: the distance to the far end when hpnicfEponUniVCTCableStatus is normal, or the distance to the fault when it reports an abnormal condition — useful for pinpointing where in the run a break or short is located.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.33
snmpwalk -v2c -c public <target> HPN-ICF-EPON-UNI-MIB::hpnicfEponUniVCTCableLength

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.33.1
snmpget -v2c -c public <target> HPN-ICF-EPON-UNI-MIB::hpnicfEponUniVCTCableLength.1

Start monitoring HP Networking EPON ONUs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EPON-UNI-MIB::hpnicfEponUniVCTCableLength OID value, configure state conditions and alerts, and monitor any HP Networking EPON ONUs from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42hpnicfEponHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.42.5hpnicfEponUniHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1hpnicfEponUniSysManHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1hpnicfEponUniSysManTableHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1hpnicfEponUniSysManEntryHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.33hpnicfEponUniVCTCableLengthHPN-ICF-EPON-UNI-MIB