hpnicfEponUniInboundLineRate

Module: HPN-ICF-EPON-UNI-MIB

OID (symbolic): HPN-ICF-EPON-UNI-MIB::hpnicfEponUniInboundLineRate

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.11

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The value of the inbound line-rate. measured with kbps. The upper limit of the line-rate is the value of hpnicfEponUniLineRateMax in the entry. It must be multiple of the value of hpnicfEponUniLineRateStep. The default value of hpnicfEponUniLineRate is the value of hpnicfEponUniLineRateMax.

What is hpnicfEponUniInboundLineRate?

The configured inbound (upstream) rate limit for this UNI port in kbps, capped by hpnicfEponUniLineRateMax and required to be a multiple of hpnicfEponUniLineRateStep — an admin lowers this to throttle a customer's upload bandwidth per their service plan.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.11
snmpwalk -v2c -c public <target> HPN-ICF-EPON-UNI-MIB::hpnicfEponUniInboundLineRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.11.1
snmpget -v2c -c public <target> HPN-ICF-EPON-UNI-MIB::hpnicfEponUniInboundLineRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.11.1 i <value>

Start monitoring HP Networking EPON ONUs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EPON-UNI-MIB::hpnicfEponUniInboundLineRate OID value, configure state conditions and alerts, and monitor any HP Networking EPON ONUs from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42hpnicfEponHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.42.5hpnicfEponUniHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1hpnicfEponUniSysManHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1hpnicfEponUniSysManTableHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1hpnicfEponUniSysManEntryHPN-ICF-EPON-UNI-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.5.1.1.1.11hpnicfEponUniInboundLineRateHPN-ICF-EPON-UNI-MIB