HPN-ICF-EOC-COMMON-MIB :: hpnicfEOCComUniCurrentSpeed

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › HPN-ICF-EOC-COMMON-MIB › hpnicfEOCComUniCurrentSpeed

hpnicfEOCComUniCurrentSpeed

Module: HPN-ICF-EOC-COMMON-MIB

OID (symbolic): HPN-ICF-EOC-COMMON-MIB::hpnicfEOCComUniCurrentSpeed

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.6

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. If the bandwidth of the interface is greater than the maximum value reportable by this object then this object should report its maximum value (4,294,967,295). For a sub-layer which has no concept of bandwidth, this object should be zero.

What is hpnicfEOCComUniCurrentSpeed?

The UNI's actual, currently negotiated or estimated bandwidth in bits per second. If the true link speed exceeds the maximum reportable value the object caps at 4,294,967,295, and it's the object an admin polls to see the real, as-negotiated rate rather than the configured hpnicfEOCComUniSpeed setting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.6
snmpwalk -v2c -c public <target> HPN-ICF-EOC-COMMON-MIB::hpnicfEOCComUniCurrentSpeed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.6.1
snmpget -v2c -c public <target> HPN-ICF-EOC-COMMON-MIB::hpnicfEOCComUniCurrentSpeed.1

Start monitoring HP Networking access aggregation devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EOC-COMMON-MIB::hpnicfEOCComUniCurrentSpeed OID value, configure state conditions and alerts, and monitor any HP Networking access aggregation devices from a single console.

How to Use in IPNetwork Monitor

Select an HP Networking access aggregation device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpnicfEOCComUniCurrentSpeed into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports an estimate of the interface's current bandwidth in bits per second. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the rate climbs well above its normal baseline, since a sustained spike often reflects real load growth or a runaway process. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.83hpnicfEOCCommonHPN-ICF-EOC-COMMON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.83.4hpnicfEOCComUniManHPN-ICF-EOC-COMMON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.83.4.1hpnicfEOCComUniManTableHPN-ICF-EOC-COMMON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1hpnicfEOCComUniManEntryHPN-ICF-EOC-COMMON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.6hpnicfEOCComUniCurrentSpeedHPN-ICF-EOC-COMMON-MIB