All MIBs › HPN-ICF-EFM-COMMON-MIB › hpnicfDot3OamErrFrameSecsSummaryWindow
hpnicfDot3OamErrFrameSecsSummaryWindow
Module: HPN-ICF-EFM-COMMON-MIB
OID (symbolic): HPN-ICF-EFM-COMMON-MIB::hpnicfDot3OamErrFrameSecsSummaryWindow
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1.12
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The amount of time (in 100ms intervals) over which the threshold is defined.
If hpnicfDot3OamErrFrameSecsSummaryThreshold frame errors occur within a window of hpnicfDot3OamErrFrameSecsSummaryWindow (in tenths of seconds), an Event Notification OAMPDU should be generated with an Errored Frame Seconds Summary Event TLV indicating the threshold has been crossed in this window.
What is hpnicfDot3OamErrFrameSecsSummaryWindow?
This is the time window, in tenths of a second (100-9000, i.e. 10-900 seconds), over which the Errored Frame Seconds Summary event's threshold is evaluated; an errored frame second is any 1-second interval with more than zero frame errors. Admins tune this to control how many seconds of history are summarized when checking for a pattern of intermittent frame errors, as opposed to counting individual error frames directly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1.12 snmpwalk -v2c -c public <target> HPN-ICF-EFM-COMMON-MIB::hpnicfDot3OamErrFrameSecsSummaryWindow
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1.12.1 snmpget -v2c -c public <target> HPN-ICF-EFM-COMMON-MIB::hpnicfDot3OamErrFrameSecsSummaryWindow.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1.12.1 i <value>
Start monitoring HP/H3C Comware switch or router (802.3ah Ethernet OAM, first-mile link) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EFM-COMMON-MIB::hpnicfDot3OamErrFrameSecsSummaryWindow OID value, configure state conditions and alerts, and monitor any HP/H3C Comware switch or router (802.3ah Ethernet OAM, first-mile link) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42 | hpnicfEpon | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.42.3 | hpnicfEfmOamMIB | HPN-ICF-EFM-COMMON-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1 | hpnicfDot3OamMIB | HPN-ICF-EFM-COMMON-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5 | hpnicfDot3OamEventConfigTable | HPN-ICF-EFM-COMMON-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1 | hpnicfDot3OamEventConfigEntry | HPN-ICF-EFM-COMMON-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.3.1.5.1.12 | hpnicfDot3OamErrFrameSecsSummaryWindow | HPN-ICF-EFM-COMMON-MIB |