HPN-ICF-DHCP-SERVER-MIB :: hpnicfDHCPSrvGlbPoolCliNbnsIPUndo

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-DHCP-SERVER-MIBhpnicfDHCPSrvGlbPoolCliNbnsIPUndo

hpnicfDHCPSrvGlbPoolCliNbnsIPUndo

Module: HPN-ICF-DHCP-SERVER-MIB

OID (symbolic): HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPSrvGlbPoolCliNbnsIPUndo

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1.12

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-write

Description: A NetBios server ip address to delete. This object is only for deleting a given ip of NetBios server.

What is hpnicfDHCPSrvGlbPoolCliNbnsIPUndo?

Write-only object for removing a single NetBIOS name server (WINS) IP address from this pool's configured NBNS list. An admin sets this to the specific NBNS address that should be removed, leaving the rest of the list (hpnicfDHCPSrvGlbPoolCliNbnsIPStr) intact.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1.12
snmpwalk -v2c -c public <target> HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPSrvGlbPoolCliNbnsIPUndo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1.12.1
snmpget -v2c -c public <target> HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPSrvGlbPoolCliNbnsIPUndo.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1.12.1 a <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hpnicfDHCPSrvGlbPoolCliNbnsIPUndo.1

Start monitoring HP networking switch/router with onboard DHCP server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPSrvGlbPoolCliNbnsIPUndo OID value, configure state conditions and alerts, and monitor any HP networking switch/router with onboard DHCP server from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.101hpnicfDHCPServerHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.2hpnicfDHCPServerTablesHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.2.4hpnicfDHCPSrvGlobalPoolParaTableHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1hpnicfDHCPSrvGlobalPoolParaEntryHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.2.4.1.12hpnicfDHCPSrvGlbPoolCliNbnsIPUndoHPN-ICF-DHCP-SERVER-MIB