HPN-ICF-DHCP-SERVER-MIB :: hpnicfDHCPServerReqTimes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-DHCP-SERVER-MIBhpnicfDHCPServerReqTimes

hpnicfDHCPServerReqTimes

Module: HPN-ICF-DHCP-SERVER-MIB

OID (symbolic): HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPServerReqTimes

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.101.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of requests received by the DHCP server.

What is hpnicfDHCPServerReqTimes?

Counts the total number of DHCP requests received by this device's DHCP server across all pools. An admin watches this counter to gauge overall DHCP request load on the device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.101.1.2
snmpwalk -v2c -c public <target> HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPServerReqTimes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.101.1.2.1
snmpget -v2c -c public <target> HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPServerReqTimes.1

Start monitoring HP networking switch/router with onboard DHCP server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-DHCP-SERVER-MIB::hpnicfDHCPServerReqTimes OID value, configure state conditions and alerts, and monitor any HP networking switch/router with onboard DHCP server from a single console.

How to Use in IPNetwork Monitor

Select an HP networking switch/router with onboard DHCP server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpnicfDHCPServerReqTimes into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of requests received by the DHCP server. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.101hpnicfDHCPServerHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.1hpnicfDHCPServerObjectsHPN-ICF-DHCP-SERVER-MIB
1.3.6.1.4.1.11.2.14.11.15.2.101.1.2hpnicfDHCPServerReqTimesHPN-ICF-DHCP-SERVER-MIB