All MIBs › HP-PROCURVE-420-PRIVATE-MIB › hpdot11OperationalRateSet
hpdot11OperationalRateSet
Module: HP-PROCURVE-420-PRIVATE-MIB
OID (symbolic): HP-PROCURVE-420-PRIVATE-MIB::hpdot11OperationalRateSet
OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute shall specify the set of data rates at which the station may transmit data. Each octet contains a value representing a rate. Each rate shall be within the range from 2 to 127, corresponding to data rates in increments of 500 kb/s from 1 Mbit/s to 63.5 Mbit/s, and shall be supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station desires to synchronize is suitable. It is also used when starting a BSS, as specified in 10.3.
What is hpdot11OperationalRateSet?
Reports the set of data rates, in 500 kbps increments, the radio is configured to transmit at and advertises in its beacon and association frames -- used to judge compatibility with clients before they associate.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1.5 snmpwalk -v2c -c public <target> HP-PROCURVE-420-PRIVATE-MIB::hpdot11OperationalRateSet
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1.5.1 snmpget -v2c -c public <target> HP-PROCURVE-420-PRIVATE-MIB::hpdot11OperationalRateSet.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1.5.1 i <value>
Start monitoring Legacy HP ProCurve 420 wireless access point with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-PROCURVE-420-PRIVATE-MIB::hpdot11OperationalRateSet OID value, configure state conditions and alerts, and monitor any Legacy HP ProCurve 420 wireless access point from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.7 | netElement | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11 | hpEtherSwitch | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.37 | hpSwitchJ8130A | HP-ICF-OID |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.7.11.37.7 | enterpriseAPdot11 | HP-PROCURVE-420-PRIVATE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.37.7.1 | hpdot11StationConfigTable | HP-PROCURVE-420-PRIVATE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1 | hpdot11StationConfigEntry | HP-PROCURVE-420-PRIVATE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.37.7.1.1.5 | hpdot11OperationalRateSet | HP-PROCURVE-420-PRIVATE-MIB |