HP-ICF-SMART-LINK-MIB :: hpicfSmartLinkTotalFlushPktsRx

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-ICF-SMART-LINK-MIB › hpicfSmartLinkTotalFlushPktsRx

hpicfSmartLinkTotalFlushPktsRx

Module: HP-ICF-SMART-LINK-MIB

OID (symbolic): HP-ICF-SMART-LINK-MIB::hpicfSmartLinkTotalFlushPktsRx

OID (numeric): 1.3.6.1.4.1.11.2.14.11.5.1.96.1.1.2

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Total number of flush packets received.

What is hpicfSmartLinkTotalFlushPktsRx?

Running total of all Smart Link flush packets this switch has received since the counter was last cleared. A steady increase confirms flush signaling between the master and slave ports is working; a count stuck at zero during a known failover points to a misconfigured control VLAN.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.96.1.1.2
snmpwalk -v2c -c public <target> HP-ICF-SMART-LINK-MIB::hpicfSmartLinkTotalFlushPktsRx

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.96.1.1.2.1
snmpget -v2c -c public <target> HP-ICF-SMART-LINK-MIB::hpicfSmartLinkTotalFlushPktsRx.1

Start monitoring HP Networking (ProCurve/Comware) switch (Smart Link master/slave failover) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-SMART-LINK-MIB::hpicfSmartLinkTotalFlushPktsRx OID value, configure state conditions and alerts, and monitor any HP Networking (ProCurve/Comware) switch (Smart Link master/slave failover) from a single console.

How to Use in IPNetwork Monitor

Select an HP Networking (ProCurve/Comware) switch (Smart Link master/slave failover) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpicfSmartLinkTotalFlushPktsRx into the Find box to locate it in the OID tree, then select it and click OK. It reports the total number of flush packets received. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.5hpicfSwitchCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.5.1hpSwitchCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.5.1.96hpicfSmartLinkMIBHP-ICF-OID
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.5.1.96.1hpicfSmartLinkObjectsHP-ICF-SMART-LINK-MIB
1.3.6.1.4.1.11.2.14.11.5.1.96.1.1hpicfSmartLinkFlushStatisticsHP-ICF-SMART-LINK-MIB
1.3.6.1.4.1.11.2.14.11.5.1.96.1.1.2hpicfSmartLinkTotalFlushPktsRxHP-ICF-SMART-LINK-MIB