HP-ICF-RATE-LIMIT-MIB :: hpIngressRateLimitPortControlMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-ICF-RATE-LIMIT-MIB › hpIngressRateLimitPortControlMode

hpIngressRateLimitPortControlMode

Module: HP-ICF-RATE-LIMIT-MIB

OID (symbolic): HP-ICF-RATE-LIMIT-MIB::hpIngressRateLimitPortControlMode

OID (numeric): 1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The mode by which this port will be Rate-Limited on ingress. If ingressRateLimitPerPortOnly is configured, there will be a single maximum percentage-based rate for the entire port. If ingressRateLimitPerQueue is configured, the values for each of the queues indicate the maximum percentage of port traffic that may be transmitted by that queue. If ingressRateLimitPerPortOnlyKbpsMode is configured, there will be a single maximum kilobits-per-second rate for the entire port. The queues are defined under hpIngressRateLimitPortPrctTable. When ingress rate-limiting is disabled, there are no maximum controls on ingress for this port. NOTE : Currently, IngressRateLimitPerPortOnlyBpsMode and ingressRateLimitPerQueueBpsMode are not supported.

What is hpIngressRateLimitPortControlMode?

Selects how this port's ingress traffic is rate-limited: disabled(1) applies no cap, ingressRateLimitPerPortOnly(2) or its Kbps variant(6) apply one aggregate limit for the whole port, and ingressRateLimitPerQueue(3) applies a separate percentage limit per queue via hpIngressRateLimitPortPrctTable; the two Bps-mode enumerations are currently unsupported.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1.2
snmpwalk -v2c -c public <target> HP-ICF-RATE-LIMIT-MIB::hpIngressRateLimitPortControlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1.2.1
snmpget -v2c -c public <target> HP-ICF-RATE-LIMIT-MIB::hpIngressRateLimitPortControlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1.2.1 i <value>

Start monitoring HP Networking switch (ICMP/bandwidth rate limiting) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-RATE-LIMIT-MIB::hpIngressRateLimitPortControlMode OID value, configure state conditions and alerts, and monitor any HP Networking switch (ICMP/bandwidth rate limiting) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.10hpicfAdminHP-ICF
1.3.6.1.4.1.11.2.14.10.2hpicfObjectModulesHP-ICF-OID
1.3.6.1.4.1.11.2.14.10.2.14hpicfRateLimitMIBHP-ICF-OID
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.10.2.14.1hpicfRateLimitObjectsHP-ICF-RATE-LIMIT-MIB
1.3.6.1.4.1.11.2.14.10.2.14.1.5hpicfIngressRateLimitPortObjectsHP-ICF-RATE-LIMIT-MIB
1.3.6.1.4.1.11.2.14.10.2.14.1.5.1hpRateLimitIngressPortConfigHP-ICF-RATE-LIMIT-MIB
1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2hpIngressRateLimitPortConfigTableHP-ICF-RATE-LIMIT-MIB
1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1hpIngressRateLimitPortConfigEntryHP-ICF-RATE-LIMIT-MIB
1.3.6.1.4.1.11.2.14.10.2.14.1.5.1.2.1.2hpIngressRateLimitPortControlModeHP-ICF-RATE-LIMIT-MIB