All MIBs › HM2-PWRMGMT-MIB › hm2PSUSlotTemperatureRange
hm2PSUSlotTemperatureRange
Module: HM2-PWRMGMT-MIB
OID (symbolic): HM2-PWRMGMT-MIB::hm2PSUSlotTemperatureRange
OID (numeric): 1.3.6.1.4.1.248.11.11.1.1.10.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The temperature range of the associated power supply slot module.
What is hm2PSUSlotTemperatureRange?
This value identifies the rated operating temperature range of the power supply slot module, from a standard range like 0 to 60 degrees C up to extended industrial ranges down to -40 degrees C. Admins check this when deploying equipment in harsh environments to confirm the installed PSU is rated for the site's conditions. A PSU showing tr-0-60(0) would need to be swapped for an extended-range unit before deployment in an unheated outdoor cabinet.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.11.1.1.10.1.9 snmpwalk -v2c -c public <target> HM2-PWRMGMT-MIB::hm2PSUSlotTemperatureRange
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.11.1.1.10.1.9.1 snmpget -v2c -c public <target> HM2-PWRMGMT-MIB::hm2PSUSlotTemperatureRange.1
Start monitoring Hirschmann HiOS industrial modular Ethernet switch (power supply unit inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-PWRMGMT-MIB::hm2PSUSlotTemperatureRange OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial modular Ethernet switch (power supply unit inventory) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.248 | hirschmann | HIRSCHMANN-GENERIC-ERROR-MIB |
| 1.3.6.1.4.1.248.11 | hm2ConfigurationMibs | HM2-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.248.11.11 | hm2PowerMgmtMib | HM2-PWRMGMT-MIB |
| 1.3.6.1.4.1.248.11.11.1 | hm2PowerMgmtMibObjects | HM2-PWRMGMT-MIB |
| 1.3.6.1.4.1.248.11.11.1.1 | hm2PowerSupplyGroup | HM2-PWRMGMT-MIB |
| 1.3.6.1.4.1.248.11.11.1.1.10 | hm2PSUSlotInfoTable | HM2-PWRMGMT-MIB |
| 1.3.6.1.4.1.248.11.11.1.1.10.1 | hm2PSUSlotInfoEntry | HM2-PWRMGMT-MIB |
| 1.3.6.1.4.1.248.11.11.1.1.10.1.9 | hm2PSUSlotTemperatureRange | HM2-PWRMGMT-MIB |