HM2-NETOBJ-MIB :: hm2NetobjectsCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-NETOBJ-MIB › hm2NetobjectsCount

hm2NetobjectsCount

Module: HM2-NETOBJ-MIB

OID (symbolic): HM2-NETOBJ-MIB::hm2NetobjectsCount

OID (numeric): 1.3.6.1.4.1.248.11.60.1.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The current number of netobject entries in the netobjects table.

What is hm2NetobjectsCount?

This read-only Integer32, ranging 0 to 1024, reports the current number of netobject entries defined in the hm2NetobjectsTable. An admin checks it to see at a glance how many named network objects (address groups) are configured on the device, without walking the whole table. For example, a value of 12 tells the admin there are 12 netobjects currently defined.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.60.1.1.1
snmpwalk -v2c -c public <target> HM2-NETOBJ-MIB::hm2NetobjectsCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.60.1.1.1.1
snmpget -v2c -c public <target> HM2-NETOBJ-MIB::hm2NetobjectsCount.1

Start monitoring Hirschmann HiOS industrial Ethernet switch (named network object groups) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-NETOBJ-MIB::hm2NetobjectsCount OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (named network object groups) from a single console.

How to Use in IPNetwork Monitor

Select a Hirschmann HiOS industrial Ethernet switch (named network object groups) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hm2NetobjectsCount into the Find box to locate it in the OID tree, then select it and click OK. The current number of netobject entries in the netobjects table. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.60hm2NetobjMibHM2-NETOBJ-MIB
1.3.6.1.4.1.248.11.60.1hm2NetobjObjectsHM2-NETOBJ-MIB
1.3.6.1.4.1.248.11.60.1.1hm2NetobjectsObjectsHM2-NETOBJ-MIB
1.3.6.1.4.1.248.11.60.1.1.1hm2NetobjectsCountHM2-NETOBJ-MIB