HM2-MGMTACCESS-MIB :: hm2WebHttpsCertPresent

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHM2-MGMTACCESS-MIBhm2WebHttpsCertPresent

hm2WebHttpsCertPresent

Module: HM2-MGMTACCESS-MIB

OID (symbolic): HM2-MGMTACCESS-MIB::hm2WebHttpsCertPresent

OID (numeric): 1.3.6.1.4.1.248.11.25.1.2.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates what HTTP certificate files are present on the device, if any.

What is hm2WebHttpsCertPresent?

Indicates what HTTPS certificate material currently exists on the device: pem(1) if a certificate file is present, or none(2) if not. Check this before enabling HTTPS if users are reporting certificate errors, since none(2) means the device needs a certificate generated first.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.25.1.2.5
snmpwalk -v2c -c public <target> HM2-MGMTACCESS-MIB::hm2WebHttpsCertPresent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.25.1.2.5.1
snmpget -v2c -c public <target> HM2-MGMTACCESS-MIB::hm2WebHttpsCertPresent.1

Start monitoring Hirschmann industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-MGMTACCESS-MIB::hm2WebHttpsCertPresent OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switches from a single console.

How to Use in IPNetwork Monitor

Select a Hirschmann industrial Ethernet switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hm2WebHttpsCertPresent into the Find box to locate it in the OID tree, then select it and click OK. Indicates what HTTP certificate files are present on the device, if any. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'pem', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHM2-TC-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.25hm2MgmtAccessMibHM2-MGMTACCESS-MIB
1.3.6.1.4.1.248.11.25.1hm2MgmtAccessMibObjectsHM2-MGMTACCESS-MIB
1.3.6.1.4.1.248.11.25.1.2hm2MgmtAccessWebGroupHM2-MGMTACCESS-MIB
1.3.6.1.4.1.248.11.25.1.2.5hm2WebHttpsCertPresentHM2-MGMTACCESS-MIB